Skip to content

Action: FUSIONPOREEXPANSIONP

Module membranefusion
Description Usage
A CV for inducing the expansion of a fusion pore from a nucleated fusion pore. used in 0 tutorialsused in 0 eggs
output value type
the value of the CV scalar

Details and examples

A CV for inducing the expansion of a fusion pore from a nucleated fusion pore.

Calculate the collective variable designed by Hub (see paper below) and implemented into PLUMED by Masone and collaborators. This CV is capable of inducing the expansion of the fusion pore from a nucleated fusion pore.

Where is the CV, is a normalization constant that makes zero the initial value of , and is the approximate radius of the fusion pore, which is defined by the number of waters and phosphateoxygens beads within a horizontal layer in the center of both membranes.

Examples

This example induces the expansion of a nucleated fusion pore () from a just nucleated fusion pore ().

Click on the labels of the actions for more information on what each action computes
tested on2.11
lMem: GROUPDefine a group of atoms so that a particular list of atoms can be referenced with a single label in definitions of CVs or virtual atoms. More details ATOMSthe numerical indexes for the set of atoms in the group=1-10752,21505-22728,23953-24420 #All the lower membrane beads.
uMem: GROUPDefine a group of atoms so that a particular list of atoms can be referenced with a single label in definitions of CVs or virtual atoms. More details ATOMSthe numerical indexes for the set of atoms in the group=10753-21504,22729-23952,24421-24888 #All the upper membrane beads.
tails: GROUPDefine a group of atoms so that a particular list of atoms can be referenced with a single label in definitions of CVs or virtual atoms. More details ATOMSthe numerical indexes for the set of atoms in the group=8-23948:12,12-23952:12,23966-24884:18,23970-24888:18 #All the lipid tails beads (from the lower and upper membrane).
waters: GROUPDefine a group of atoms so that a particular list of atoms can be referenced with a single label in definitions of CVs or virtual atoms. More details ATOMSthe numerical indexes for the set of atoms in the group=24889-56589  #All the water beads.
po4: GROUPDefine a group of atoms so that a particular list of atoms can be referenced with a single label in definitions of CVs or virtual atoms. More details ATOMSthe numerical indexes for the set of atoms in the group=2-23942:12,23957-24875:18 #All the lipid phosphateoxygens beads.

fusionPoreExpansion: FUSIONPOREEXPANSIONPA CV for inducing the expansion of a fusion pore from a nucleated fusion pore. More details UMEMBRANEall the beads of the upper membrane=uMem LMEMBRANEall the beads of the lower membrane=lMem TAILSall the tail beads of the system=tails WATERSall the water beads of the system=waters PHOSPHATEOXYGENSall the lipid phosphateoxygens beads of the system=po4 NSMEMthe number of slices of the membrane fusion cylinder=85 Dhorizontal layer thickness, it depends on the Z separation of the membranes=7.0 R0normalization constant that makes 0 the initial value of the CV=0.57 MOVINGRESTRAINTAdd a time-dependent, harmonic restraint on one or more variables. More details ... ARGthe labels of the scalars on which the bias will act=fusionPoreExpansion STEP0This keyword appears multiple times as STEPx with x=0,1,2,=0 AT0ATx is equal to the position of the restraint at time STEPx=0.0 KAPPA0KAPPAx is equal to the value of the force constants at time STEPx=10000.0 STEP1This keyword appears multiple times as STEPx with x=0,1,2,=500000 AT1ATx is equal to the position of the restraint at time STEPx=0.75 KAPPA1KAPPAx is equal to the value of the force constants at time STEPx=10000.0 ...
PRINTPrint quantities to a file. More details ARGthe labels of the values that you would like to print to the file=fusionPoreExpansion FILEthe name of the file on which to output these quantities=COLVAR STRIDE the frequency with which the quantities of interest should be output=1

Input

The atoms that serve as the input for this action are specified using one or more of the keywords in the following table.

Keyword Type Description
UMEMBRANE atoms all the beads of the upper membrane
LMEMBRANE atoms all the beads of the lower membrane
TAILS atoms all the tail beads of the system
WATERS atoms all the water beads of the system
PHOSPHATEOXYGENS atoms all the lipid phosphateoxygens beads of the system

Full list of keywords

The following table describes the keywords and options that can be used with this action

Keyword Type Default Description
UMEMBRANE input none all the beads of the upper membrane
LMEMBRANE input none all the beads of the lower membrane
TAILS input none all the tail beads of the system
WATERS input none all the water beads of the system
PHOSPHATEOXYGENS input none all the lipid phosphateoxygens beads of the system
NSMEM compulsory none the number of slices of the membrane fusion cylinder
D compulsory none horizontal layer thickness, it depends on the Z separation of the membranes
R0 compulsory none normalization constant that makes 0 the initial value of the CV
NUMERICAL_DERIVATIVESThis keyword do not have examples optional false calculate the derivatives for these quantities numerically
NOPBCThis keyword do not have examples optional false ignore the periodic boundary conditions when calculating distances
DSMEMThis keyword do not have examples optional not used thickness of the slices of the membrane fusion cylinder
HMEMThis keyword do not have examples optional not used parameter of the step function θ(x,h) for the membrane fusion
VOThis keyword do not have examples optional not used beads' molecular volume
HThis keyword do not have examples optional not used parameter of the step function θ(x,h) for the fusion pore expansion
RMAXThis keyword do not have examples optional not used to avoid effects of membrane undulations in large membranes (more than 256 lipids)
XCYLThis keyword do not have examples optional not used X coordinate of the fixed cylinder, if not present this will be calculated
YCYLThis keyword do not have examples optional not used X coordinate of the fixed cylinder, if not present this will be calculated

References

More information about how this action can be used is available in the following articles: